Related Experiment Video
Updated: Apr 28, 2026

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Comparative Analysis of Pulmonary Function in Rice Mill Workers Versus Unexposed Controls: A Pilot Cross-Sectional
Prasath Sekar1, B Jaya1, Sumitra Sudharkodhy1
1Physiology, Karpaga Vinayaga Institute of Medical Sciences and Research Centre, Madhuranthagam, IND.
None:
Introduction Rice milling is a major agro-based industry in India and employs a large number of workers who are chronically exposed to organic and inorganic dust generated during milling operations. Inhalation of rice husk dust, silica residues, fungal spores, and other airborne contaminants may contribute to airway inflammation, fibrosis, and ventilatory impairment. However, standardized spirometric data from Indian rice mill workers remain limited. This study aimed to compare pulmonary function parameters between rice mill workers and unexposed controls. Materials and methods A cross-sectional study was conducted at the Department of Physiology, Karpaga Vinayaga Institute of Medical Sciences, Madhuranthagam. A total of 100 male participants aged 30-60 years were included; of these, 50 were exposed, and 50 were unexposed. Exclusion criteria included smoking, pre-existing respiratory or cardiac disease, inability to perform spirometry adequately, prior exposure to other occupational dust, and recent or active acute respiratory infection. Spirometry was performed using a Medicaid Smart Soft USB software spirometer (Medicaid Systems, Jalandhar, Punjab, India), measuring forced vital capacity (FVC), forced expiratory volume in one second (FEV₁), FEV₁/FVC ratio, and peak expiratory flow rate (PEFR) for both groups. Data were analyzed using SPSS Version 31 (IBM Corp., Armonk, NY, US). Results The PFT of the Rice mill workers showed a significant decrease in FVC (1.96 ± 0.22 L), FEV₁ (1.69 ± 0.21 L), and PEFR (4.47 ± 1.89 L/s) compared to controls (p < 0.05). However, FEV₁/FVC ratio is more than 70%, suggesting a restrictive pattern of lung involvement, with a restrictive spirometric pattern.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...