Comparability of venous versus capillary hemoglobin A1c measurements
Em Yunir1,2, Syahidatul Wafa1,2, Nuri Dyah Indrasari3
1Division of Endocrinology, Metabolism, and Diabetes, Department of Internal Medicine, Dr. Cipto Mangunkusumo National General Hospital, Faculty of Medicine Universitas Indonesia, Jalan Diponegoro No. 71, 10430 Jakarta, Indonesia.
Background:
Hemoglobin A1c (HbA1c) level measurement using venous blood sample is essential for diabetes management. However, this method is not always readily accessible in primary health care in Indonesia. This study aimed to evaluate the comparability of venous versus capillary blood HbA1c measurement.
Methods:
A cross-sectional study was performed, involving subjects with and without type 2 diabetes (T2D). Venous blood samples were analyzed using a high-performance liquid chromatography (HPLC) analyzer. Simultaneously, capillary blood samples from the same subjects were analyzed using a point-of-care testing (POCT) instrument based on capillary electrophoresis (CE). Passing-Bablok regression was performed to assess constant or proportional bias between methods. Bland-Altman test was conducted to evaluate the agreement of HbA1c measurement between venous and capillary.
Results:
Out of 162 subjects, 129 (79.6%) had diabetes, 9 (5.5%) had newly developed diabetes, and 24 (14.8%) did not have diabetes. Mean venous HbA1c was higher (7.79%) than capillary HbA1c (7.49%). Bland-Altman analysis showed that mean bias for all subjects was -0.30%, with 93.8% of subjects within the limit of agreement. Besides, mean bias between subjects with venous HbA1c < 6.5% and ≥ 6.5% was - 0.14% and -0.38%, respectively. Meanwhile, Passing-Bablok regression showed no constant and proportional bias in subjects with venous HbA1c < 6.5%. However, constant and proportional bias were found in all subjects and in those with venous HbA1c ≥ 6.5%.
Conclusions:
Capillary HbA1c results have a good agreement with venous HbA1c. Capillary HbA1c POCT method can be considered as an alternative for monitoring diabetes. HbA1c measurement ≥ 6.5% should be interpreted with caution.
Supplementary Information:
The online version contains supplementary material available at 10.1007/s13340-026-00889-3.
More Related Videos
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Bioequivalence Data: Statistical Interpretation
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure