Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Evaluation of physiology-based models for noninvasive blood pressure estimation using pulse arrival time
Artur Poliński1, Javier Rosell-Ferrer2
1Department of Biomedical Engineering, Faculty of Electronics, Telecommunication and Informatics, BioTechMed Center, Gdańsk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland. artur.polinski@pg.edu.pl.
None:
A noninvasive and nonocclusive blood pressure (BP) measurement method is essential for ambulatory and long-term monitoring. It appears that in the case of wearable systems for continuous pressure measurement, the technique utilizing the dependence of pulse wave velocity on pressure is particularly useful. However, it has some limitations, e.g., accuracy. A generalized, nonlinear model, with respect to physiological parameters, for BP estimation, utilizing information about pulse arrival time (PAT), pulse period (RR), and respiratory activity phase (resp), is proposed and analysed. Analyses have been conducted using a publicly available database. The models are compared against each other using various measures such as correlation, root mean square, Akaike information criterion, Bayesian information criterion, and minimum description length. An optimal model, superior to those presented in the literature, is recommended for each measure. In addition, the influence of individual signals on the pressure estimation error was analysed. The results show that simple models generate large errors in BP estimation. Including more parameters improves the results, but the errors are still relatively large. The presented results suggest that the considered signals, i.e., PAT, RR, and resp, contain incomplete information about the current pressure value.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical...