Accuracy evaluation of calibrator value assignment in 25-hydroxyvitamin D LC-MS/MS assays: a metrological
1Reference Measurement Laboratory, Shanghai Center for Clinical Laboratory, Shanghai, China.
Clinical Chemistry and Laboratory Medicine
|April 28, 2026
Abstract
No abstract available in PubMed .
Keywords:
25-hydroxyvitamin Dcalibratorsliquid chromatography-tandem mass spectrometry (LC-MS/MS)metrological traceabilitystandardizationMore Related Videos
10:22Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties Lactuca sativa L. and Crop Wild Relatives Lactuca spp.
Published on: June 30, 2020
15.1K
08:53Quantitative and Qualitative Method for Sphingomyelin by LC-MS Using Two Stable Isotopically Labeled Sphingomyelin Species
Published on: May 7, 2018
8.6K
Related Concept Videos
Instrument Calibration
1.4K
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
1.4K
Data Validation
3.7K
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
Key parameters for method validation include:
3.7K
Calibration Curves: Linear Least Squares
4.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.3K