Discriminative ability for abnormal ventilatory function using acoustic pattern of inhale and exhale in patients
Kyu-Min Kang1, Hyun-Seok Kim2, Woo-Jin Kim1
1Department of Anesthesiology and Pain Medicine, Asan Medical Center, Brain Korea 21 Project, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Background:
Despite various available methods for monitoring a patient's respiratory system, conventional monitors provide limited ventilatory function information. This study explored the feasibility of intraoperative lung sound patterns to discriminate preoperatively diagnosed ventilatory dysfunction.
Methods:
Forty-five patients who had undergone preoperative pulmonary function testing were enrolled for analysis, comprising 15 patients per normal, obstructive, and restrictive group. High-fidelity lung sounds were recorded intraoperatively using esophageal stethoscopes equipped with digital microphone devices. After signal processing, morphological features of the acoustic data, including the inhale/exhale peak ratio (I/Ep), were extracted. Their discriminative abilities for obstructive and restrictive types were assessed and compared with conventional monitoring parameters.
Results:
I/Ep showed strong discriminative performance, with an area under the receiver operating characteristic curve of 0.950 (95% CI: 0.887-0.991) for obstructive and 0.950 (95% CI: 0.867-0.995) for restrictive types. The median values of I/Ep were 2.9 in the restrictive, 2.2 in the normal, and 1.5 in the obstructive group (P < 0.001). Conventional ventilatory parameters (compliance, peak inspiratory pressure, and slope of end-tidal CO2) did not significantly differ among the groups.
Conclusions:
Our study demonstrated that the I/Ep derived from intraoperative acoustic data differed according to preoperatively diagnosed ventilatory dysfunction. Hence, acoustic inhale and exhale patterns contain clinically useful information not captured by conventional ventilator parameters. Further studies are warranted to explore the clinical application of acoustic feature analysis for real-time intraoperative monitoring.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Related Concept Videos
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: