Performance comparison of a wired zero-heat-flux sensor and wireless thermistor patch with esophageal probe for core
Jeayeon Park1,2, Su Jong Yu3,4, Hyunsoo Chung5,6
1Department of Gastroenterology, Ajou University School of Medicine, Suwon, Korea.
Abstract:
Accurate measurement of body temperature is essential in clinical practice; however, direct assessment of core temperature is invasive. Consequently, there is an increasing demand for non-invasive yet accurate methods. In this study, we compared two non-invasive techniques - a wired zero-heat-flux sensor (W⁺ZHF) and a wireless thermistor patch (W⁻TP) - against core temperature measurements obtained from an esophageal probe (EP). This prospective study included consecutive subjects who underwent esophagogastroduodenoscopy for health screening. The EP served as the reference for core temperature. Simultaneously, paired temperature readings were taken using W⁺ZHF and W⁻TP. Agreement between EP and each wearable device (W⁺ZHF and W⁻TP) was evaluated using subject-level Bland-Altman analysis, Pearson correlation coefficients, and intraclass correlation coefficients (ICC). Paired t-tests were used for descriptive comparison, and linear mixed-effects models were applied to account for repeated measurements within subjects. Among the 24 subjects, 5 (20.8%) were male and 19 (79.2%) were female, with a mean age of 32.8 ± 7.4 years. The mean temperatures measured by W⁺ZHF, W⁻TP, and EP were 36.56 ± 0.30°C, 36.61 ± 0.32°C, and 36.50 ± 0.26°C, respectively. Subject-level Bland-Altman analysis demonstrated a small bias between W⁺ZHF and EP (0.06°C; 95% confidence interval [CI], -0.04-0.15), with 95% limits of agreement (-0.42-0.53°C). The Pearson correlation coefficient between W⁺ZHF and EP was 0.63, and the ICC indicated moderate to high agreement (ICC, 0.62; 95% CI, 0.31-0.82). In contrast, W⁻TP showed greater variability in agreement with EP. Direct comparison between W⁺ZHF and W⁻TP revealed differences in agreement. These findings were consistent in linear mixed-effects models accounting for repeated measurements. Among the non-invasive devices evaluated, W⁺ZHF showed the closest agreement with EP measurements, although the predefined equivalence criterion was not formally met. These findings nonetheless suggest a promising role for zero-heat-flux technology in non-invasive estimation and support its further development in wearable devices.
More Related Videos
06:43Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...