Related Experiment Video
Updated: May 1, 2026

Preparing Adherent Cells for X-ray Fluorescence Imaging by Chemical Fixation
Published on: March 12, 2015
Evaluation of reagents for suspension-assisted total reflection X-ray fluorescence element analysis in biomedical
Sebastian Hauser1, Marit Veit1, Kerstin Leopold2
1Institute of Analytical and Bioanalytical Chemistry (IABC), Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany.
Abstract:
In biomedical research, it is essential to be able to precisely and reliably quantify trace and microelements in complex biological matrices in order to identify deficiencies and understand disease mechanisms. Analytical methods that are sensitive, robust, and environmentally friendly are preferable. Suspension-assisted total reflection X-ray fluorescence spectrometry (SA-TXRF) is a simple to perform, multielement analytical method that can quantify trace elements in suspensions containing minute sample amounts. In this work, a systematic study comparing five different suspension reagents, namely concentrated and diluted nitric acid, Triton X-100, Triton X-114, and ultrapure water, for SA-TXRF analysis of trace and microelements in three biological reference materials (NIST 1577c, NIST 1486, and ERM-BB186) is presented. The analytical performance is compared in terms of trueness, precision, and sensitivity, and the resulting SA-TXRF methods were assessed for greenness using the Analytical Greenness Metric for Sample Preparation (AGREEprep). As a result, water is recommended as suspension reagent for soft biological material, while for hard biological material, i.e., bone meal, best results were achieved using the surfactant Triton X-114. All of the presented SA-TXRF methods demonstrate improved greenness compared to the standard method (EPA Method 3052), which involves sample preparation by microwave-assisted digestion.
More Related Videos
08:26Cell Culture on Silicon Nitride Membranes and Cryopreparation for Synchrotron X-ray Fluorescence Nano-analysis
Published on: December 10, 2019
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
Related Concept Videos
Atomic Emission Spectroscopy: Overview
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Fluorescence Spectroscopy
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Emission Spectroscopy: Lab