Related Experiment Video
Updated: May 1, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Biomechanical Assessment of Femur Fracture Fixation Using Modified Locking Compression Plate Made of Biodegradable
Girish Chandra1, Rajdeep Ghosh2,3, Vivek Verma4
1Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, India.
None:
Transverse femoral fractures heal through a complex secondary healing process, often stabilized using locking compression plates (LCPs) that maintain compression across an interfragmentary gap. Conventional LCPs made of non-biodegradable Ti-alloys provide adequate mechanical support but can induce stress-shielding in newly formed callus and bone, necessitating revision surgeries. To address this, Mg-based biodegradable LCPs have been actively investigated. However, their clinical translation and commercial adoption remain limited, primarily due to concerns regarding their lower mechanical strength and fixation stability compared to Ti-alloys. Embossed structure-based LCP (ELCP) was designed previously to enhance its mechanical performance. However, its biomechanical feasibility under physiological loading across different fracture healing phases has not yet been systematically evaluated. In the present study, fractured femur models for two fixation strategies, a conventional LCP (M2) and the ELCP (M3), were developed. These strategies were tested using three candidate biomaterials (one non-biodegradable material, Ti-alloy, and two biodegradable materials, Mg-alloy and PLA/50% Mg composite). Three physiological loading conditions corresponding to the healing and early repair phases were applied. The results showed that although Ti-alloy-based conventional LCPs provided superior fixation strength, Mg-alloy-based ELCPs also performed substantially better than conventional LCPs, as reflected by high safety factors ranging from 1.81 to 3.42, unlike composite-based plates. Moreover, Mg-alloy-based ELCPs exhibited higher interfragmentary strain (within or above the ideal strain range) in the callus compared to Ti-alloy-based LCPs, which might promote faster callus strengthening. Thus, Mg-alloy-based ELCPs could represent a viable alternative to conventional LCPs by offering adequate fixation strength while potentially reducing stress-shielding.
More Related Videos
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024