Related Experiment Video
Updated: May 1, 2026

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Establishment of local diagnostic reference levels for trunk computed tomography examinations at governmental
Amjad Ayyad1, Yasser Alajerami1, Ahmed Najim2,3
1Department of Medical Imaging, Faculty of Applied Medical Sciences, Al- Azhar University, Gaza Strip, Palestine.
Abstract:
To establish the local diagnostic reference levels (LDRLs) for trunk multi-slice CT (MSCT) examinations in the Gaza Strip, Palestine. This cross-sectional study included adult oncology patients undergoing trunk MSCT at two governmental hospitals in Gaza Strip; Al Shifa Medical Complex (SMC) and Al Aqsa Martyrs Hospital (AMH), using an adapted dose survey booklet. Data collected from July 2019 to March 2020 included patient characteristics, volumetric CT dose index (CTDIvol) and dose length product (DLP). Descriptive, univariate and multivariate analyses identified key factors affecting radiation dose, and the coefficient of variation between scanner- and software-derived dose values was also determined. A total of 170 trunk CT examinations were analysed (57.1% SMC, 42.9% AMH). 72.94% were female; the mean age of the participants is 53.1 ± 15.8 years, and the mean body mass index was 30 ± 6.1. The estimated LDRLs for trunk CT were 13 mGy for CTDIvol and 1010.4 mGy·cm for DLP. There was notable variation between hospitals in CTDIvol and DLP (p < 0.001). At SMC, factors such as tube current, peak kilovoltage, scan length, pitch and BMI significantly affected dose indices. In contrast, at AMH, the main influences were tube current and scan length. CTDIvol had a greater impact on DLP than scan length at both locations. LDRLs for trunk CT scans in the Gaza Strip were established and found to be generally comparable to international benchmarks. Notable variation in doses between hospitals indicates potential for improvement through standardising protocols, managing scan lengths and using techniques tailored to patient size.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET