Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Quantifying The Impact of Textile Thickness and Contact Pressure on Watch-type Bone-Conduction Phonocardiogram: A
None:
Phonocardiogram (PCG) has increasingly been applied to out-of-hospital monitoring and home health management. Among these, Bone-Conduction PCG (BCPCG) has emerged as a promising solution for long-term wearable cardiac sound monitoring due to its superior noise resistance and privacy protection. However, its acquisition is susceptible to variations in textile thickness and contact pressure, exacerbating instability in critical event detection. To systematically evaluate these influencing mechanisms, this study quantifies the impact of varying textile thickness (0-5.92 mm) and pressure (0-15 N) combinations on BCPCG. First, an equivalent mass-damping-spring model was employed to assess the transmission dynamics qualitatively. Subsequently, rigorous experiments were designed to collect signals and compare key features, including S1/S2 localization accuracy, pseudo signal-to-noise ratio (PSNR), and spectral centroid (SC). The results demonstrate that BCPCG signals remain relatively stable within the 0-2 N range, exhibit slight degradation between 3-5 N, and experience a marked decline under high pressure (10-15 N), where the PSNR drops by nearly 50% and S1 localization accuracy decreases to 70.27%. This may stem from tissue tremors and amplified high-frequency noise under high pressure. Meanwhile, textile thickness at low pressures primarily affects high-frequency components without significantly impacting localization accuracy. Finally, a classification model based on Top-11 features identified contact pressure intervals (0-2 N, 3-5 N, 10-15 N), and the macro-averaged AUC reached 0.985. This study validates the feasibility of pressure-inverse inference using BCPCG features, providing theoretical and practical foundations for real-world applications.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)