Objectives:
Deep learning models developed for the classification of radiological reports have lacked explainability. We aimed to validate and explain a pretrained classification model by applying it to the removal of confounding data from a radiological dataset.
Methods:
Two radiologists categorized 2038 anonymized MRI head free-text radiology reports for abnormality and for small vessel disease presence. Of these reports, 80% (n = 1630) were used to fine-tune pretrained transformer models to classify scans. Five-fold cross-validation was used in model development. The models were tested on the remaining 20% of the reports (n = 408). SHapley Additive exPlanations (SHAP) were used to explain the results.
Results:
The models exhibited excellent classification performance, with a mean receiver operating characteristic (ROC) area under the curve (AUC) of 0.98 for abnormality classification and 0.99 for small vessel disease classification. SHAP highlighted relevant words in both cases.
Conclusions:
This application validated the use of a pretrained transformer in detecting confounding data in research cohorts, and exhibited explainable results that allow the models' decisions to be understood. By highlighting the specific report terms that drive each prediction, the explainable model output can be reviewed and critiqued by subject matter experts, supporting trust, error analysis, and iterative refinement of AI tools within clinical workflows.
Advances In Knowledge:
This application demonstrates the feasibility of explainable report classification, and the fine-tuned model could be used in future for automatic removal of confounding data from radiology datasets, while providing transparent, case-level justifications that support audit, governance, and clinician acceptance.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...