Related Experiment Video
Updated: May 3, 2026

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
Identification and verification of worst-case radiological transport scenarios for Ireland: A simulation-based
Marc Sturrock1, Robert Ryan2, Kevin Kelleher2
1Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin, Ireland; Office of Radiation Protection and Environmental Monitoring, Environmental Protection Agency, McCumiskey House, Richview, Clonskeagh Road, Dublin, 14, Ireland.
Abstract:
This study presents a comprehensive simulation-based assessment of potential transboundary radiological transport to Ireland from six nuclear facilities in the United Kingdom and France, utilising weather data over a fourteen-year period (2011-2024). Systematic screening of 2.2 million HYSPLIT atmospheric dispersion simulations identified eighteen worst-case scenarios representing maximum ground deposition, maximum air concentration, and minimum warning time. Independent verification using FLEXPART and HYSPLIT demonstrated expected inter-model variability (factor of 1-10), with both Lagrangian models providing consistent risk assessment brackets. Heysham, despite its complex 19-isotope AGR source term, produced negligible radiological doses to Ireland (<0.01 mSv), substantially below intervention thresholds. More distant continental facilities (Flamanville, Paluel, Sizewell B) showed low but measurable doses (0.1-4.6 mSv), remaining well below the 50 mSv sheltering threshold. This study addresses urgent-phase protective actions only; transitional-phase food chain countermeasures are beyond scope. Hinkley Point C (under construction) showed elevated but sub-threshold doses (0.3-8.5 mSv). However, the cancelled Wylfa Newydd gigawatt-scale project (the site is now proposed for small modular reactors), owing to its extreme proximity to Ireland, exhibited concerning dose predictions: FLEXPART calculated 19.6 mSv under maximum deposition conditions (May 2024 scenario), approaching the 50 mSv sheltering threshold, whilst HYSPLIT predicted 4.5 mSv. This inter-model variability (factor of ∼5) highlights genuine uncertainty for near-source impacts but converges on a critical finding: were a gigawatt-scale reactor constructed at the Wylfa site, severe accidents during specific meteorological patterns could require protective actions in Ireland. Machine learning models (XGBoost) achieved validation accuracies of 85-93% for rapid impact prediction, whilst global sensitivity analysis revealed that meteorological conditions, rather than release parameters, dominate consequence severity. These findings provide quantitative assurance that existing nuclear infrastructure poses low transboundary risk to Ireland well below urgent-phase intervention thresholds (sheltering and evacuation), whilst demonstrating that facility proximity constitutes the dominant factor determining potential radiological impact.
More Related Videos
Related Concept Videos
Radiation: Applications
The average...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...