Assessing calibration methods for fenuron determination in carrot juice via GC-MS with salt-assisted switchable
Süleyman Bodur1,2,3, Sezin Erarpat Bodur1, Sude Oflu1,4
1Department of Chemistry, Faculty of Art and Science, Yıldız Technical University, 34220, İstanbul, Türkiye.
A new analytical method using salt-assisted switchable solvent-liquid phase microextraction (SA-SS-LPME) accurately determines fenuron in carrot juice. Quadruple isotope dilution (ID4) proved most accurate for method validation.
Area of Science:
- Analytical Chemistry
- Food Safety Analysis
- Environmental Science
Background:
- Fenuron is a herbicide that can contaminate food products.
- Accurate quantification of fenuron in food matrices like carrot juice is crucial for consumer safety.
- Existing analytical methods may lack the sensitivity or precision required for trace-level detection.
Purpose of the Study:
- To establish a precise and accurate analytical method for fenuron determination in carrot juice.
- To evaluate the effectiveness of salt-assisted switchable solvent-liquid phase microextraction (SA-SS-LPME) for enhancing detection limits.
- To compare the accuracy and precision of different calibration methods, including quadruple isotope dilution (ID4).
Main Methods:
- Development and optimization of the SA-SS-LPME technique coupled with Gas Chromatography-Mass Spectrometry (GC-MS).
- Comparison of external standard calibration, matrix-matching calibration, internal standard calibration, and ID4 calibration strategies.
- Validation of the method by assessing linearity, limit of detection (LOD), limit of quantitation (LOQ), and percent recovery.
Main Results:
- The SA-SS-LPME-GC-MS method achieved low LOD (0.05 mg/kg) and LOQ (0.15-0.17 mg/kg) values.
- ID4 calibration demonstrated superior accuracy and precision, with recovery rates of 99.6%-102.0%.
- Other calibration methods showed varying degrees of accuracy and recovery, with external standard calibration yielding 104.5%-118.1% recovery.
Conclusions:
- SA-SS-LPME-GC-MS is a highly effective technique for fenuron analysis in carrot juice.
- The quadruple isotope dilution (ID4) strategy offers significant advantages in terms of accuracy and precision for this analytical method.
- This validated method provides a reliable tool for monitoring fenuron contamination in food products.
More Related Videos
05:20Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
08:22Author Spotlight: A New and Efficient Method for Comprehensive Metabolite Cytotoxicity Assessment of Triazole Pesticides in Plants
Published on: December 22, 2023
