Abstract:
Aiming to improve cooling and dehumidification performance in air conditioning systems and to meet the trend toward environmentally friendly refrigerants, this study proposes a coupled system that combines a CO2 transcritical refrigeration cycle (CTRC) with a liquid desiccant dehumidification cycle. The system takes advantage of high-grade waste heat from the exothermic side of the CTRC to drive the regenerating process of the liquid desiccant dehumidification. A cooling evaporator is adopted to cool indoor air, while another evaporator (i.e., Evaporator II) is utilized to cool the concentrated solution, improving dehumidification capacity and enabling independent control of sensible and latent heat loads. Through thermodynamic modeling and the exergy analysis model, a mathematical model of the system is developed to examine how key parameters (such discharge pressure and the CO2 mass flow rate ratio in Evaporator II (λ)) affect performance and to analyze exergy loss features. Results show that the system's coefficient of performance (COP) and dehumidification coefficient of performance (COPdeh) initially rise and then fall with increasing CTRC discharge pressure, achieving an optimal pressure of around 10,500 kPa (COP up to 4.32) under a specific working condition, surpassing those of standalone CTRC systems. Properly increasing λ enhances dehumidification capacity and energy efficiency, with a low specific dehumidification energy (SDE) of 0.2033 kWh/kg, indicating high economic efficiency. Most exergy losses occur in the CO2-solution heat exchanger and dehumidifier (over 60% of total losses). The system's maximum exergy efficiency reaches 12.4%, leaving room for further improvements. This coupled system offers an efficient, eco-friendly way for air conditioning in high-humidity environments, combining cooling and dehumidification with the potential for energy recovery.
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
The Carnot Cycle
What could be the theoretical limit to the efficiency of a heat engine? The...
Efficiency of The Carnot Cycle
The Carnot Cycle and the Second Law of Thermodynamics
Since the individual steps in a Carnot cycle can be reversed, the entire cycle is, thus, reversible. If a Carnot cycle is reversed, it becomes a Carnot refrigerator. It extracts heat Qc from a cold reservoir at...
Sublimation
The Joule and Joule–Thomson Experiments