Related Experiment Video
Updated: Jun 10, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Evaluation of Individual T1w-DIXON Contrasts for Subtraction Generation in Dynamic Contrast-Enhanced Breast MRI
Shirley-Maria Christian1, Sebastian Bickelhaupt2, Dominique Hadler2
1Gynecology Department, Klinikum Darmstadt, 64283 Darmstadt, Germany.
None:
Background/Objectives: To evaluate the influence of different DIXON contrasts on the quality of subtraction images in dynamic breast MRI using maximum intensity projections (MIPs). Methods: This retrospective study included n = 40 women (median age: 53.5 years, range 23-83) undergoing clinically indicated breast MRI (3T). For each MRI examination, two independent readers individually evaluated GBCA-enhanced subtraction MIPS for different timepoints (n = 5) and DIXON contrasts (n = 4) per breast, resulting in a total of 800 individual evaluations. Evaluations comprised (a) qualitative measures, using Likert-scores for artefact strength, breast parenchyma visibility, lesion visibility and reading confidence; and (b) signal intensity, measured in three regions of interest with the apparent signal-to-noise ratio (aSNR) and apparent contrast-to-noise ratio (aCNR) calculated. The evaluation results were analysed to identify differences between DIXON contrasts. Results: The "only water" DIXON contrast at ~120s after GBCA injection achieved the highest lesion conspicuity and reading confidence scores and lowest artefact scores; however, its performance was not statistically significant (p > 0.05) compared to the "in-phase" and "opposed-phase" subtractions. The aCNR at the second timepoint was slightly, but not significantly (p > 0.05), lower than the first timepoint, whilst aSNR increased significantly from the first to second timepoint in all contrasts. Conclusions: Subtraction MIPs derived from the "only water" DIXON contrast achieved the highest qualitative scoring for lesion conspicuity and confidence, with the aSNR increasing and aCNR decreasing between the first and second timepoints.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Magnetic Resonance Imaging