Accuracy of Measuring Blood Pressure with a Volume Clamp-Based Finger Cuff vs. Arterial Line at Rest and During
Anna Titz1, Julian Müller1, Simon Raphael Schneider1
1Department of Pulmonology, University Hospital Zurich, 8091 Zurich, Switzerland.
Abstract:
Background/Objective: Continuous blood pressure (BP) monitoring is essential in clinical settings, where rapid hemodynamic changes influence patient management. While intra-arterial measurement remains the reference standard, non-invasive volume-clamp systems offer a potential alternative. We assessed the accuracy of finger-cuff-based continuous BP monitoring compared to invasive measurement in patients with pulmonary hypertension (PH). Methods: This post hoc analysis from a crossover RCT included PH patients who underwent repetitive hemodynamic assessments at rest and during exercise. The participants had simultaneous invasive BP monitoring via the radial artery and a non-invasive finger-cuff device (Finapres® NOVA Basic). The mean blood pressure (mBP) was compared at rest, 50% of the maximal workload, and at the end of exercise using Bland-Altman and Taffé analysis. Results: In the study, 24 patients (seven female; 59 ± 14 years) contributed 385 paired mBP measurements. The invasive and non-invasive methods showed similar values at rest (96.1 ± 16.7 vs. 96.4 ± 17.2 mmHg) and during maximal exercise (106.8 ± 18.6 vs. 111.8 ± 21.6 mmHg). The overall Bland-Altman bias was 2.8 mmHg with wide limits of agreement (-39.6 to 45.3 mmHg), which remained broad across all exercise intensities. The Taffé analysis revealed a non-uniform, directionally dependent bias: the non-invasive system overestimated the mBP at low pressures and underestimated it at higher pressures. The measurement variability was substantially greater for the non-invasive method than for the invasive reference. Conclusions: In PH patients, finger-cuff-based continuous BP monitoring demonstrated acceptable group-level agreement but insufficient individual-level accuracy for clinical decision-making.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: