Artificial intelligence-enhanced wearable technology enables ventricular arrhythmia prediction
Maarten Z H Kolk1,2, Diana My Frodi3, Joss Langford4,5
1Department of Clinical and Experimental Cardiology, Amsterdam UMC Location University of Amsterdam, Heart Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
Aims:
Patterns in physical behaviour may be associated with an increased risk of ventricular arrhythmia. We examined associations between temporal dynamics in physical behaviour measured through wearable technology and the risk of ventricular arrhythmia.
Methods And Results:
The multicentre, prospective SAFEHEART study recruited 303 patients with an implantable cardioverter-defibrillator (ICD) from May 2021 to September 2022. Continuous physical behaviour data were collected over 365 consecutive days and nights using wearable accelerometers. We characterized each 28-day behavioural time series using statistical summary indices and deep representations learned by neural networks. Logistic regression analyses were used to estimate the associations between physical behaviour and the subsequent risk of ventricular arrhythmia as detected by ICD and treated appropriately. Predictive performance was assessed using k-fold cross-validation and quantified by the area under the receiver operating characteristic curve (AUROC). From the SAFEHEART cohort, 277 patients and 56 ventricular arrhythmia were analysed, contributing to a total of 64 995 days of behavioural data. Reduced numbers of daily physical activity bouts and low day-to-day variation in sleep characteristics were associated with an increased risk of an arrhythmic event. Deep representations improved the predictive performance, with an AUROC of 0.74 ± 0.05, compared with statistical summary indices with an AUROC 0.67 ± 0.14 (P = 0.05 for comparison).
Conclusion:
Our findings suggest that behavioural patterns captured through wearable technology are independently associated with ventricular arrhythmia, particularly when these are characterised by deep representations.
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Mechanism of Cardiac Arrhythmias
Holter Monitor: 24-Hour Monitoring