Related Experiment Video
Updated: Jul 6, 2026

12:17
Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
The Initial Middle Eastern Experience With the Alterra Adaptive Pre-Stent: Single-Center Outcomes From Saudi Arabia
Mohamed Al Nasef1,2,3, Bandar Al Shehri4, Khalid Al Naji4
1Pediatric Cardiology and Adult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
CJC Pediatric and Congenital Heart Disease
|May 4, 2026
Summary
The Alterra Adaptive Pre-Stent offers a new transcatheter pulmonary valve replacement option for complex right ventricular outflow tracts. This first Middle Eastern experience shows the device is safe and effective.
Area of Science:
- Cardiology
- Interventional Cardiology
- Congenital Heart Disease
Background:
- The Alterra Adaptive Pre-Stent, used with the Edwards SAPIEN 3 valve, provides a novel transcatheter option for patients with severely dilated right ventricular outflow tracts (RVOTs).
- These patients were previously unsuitable for conventional transcatheter pulmonary valve replacement (TPVR).
- No prior experience with this system had been reported from the Middle East.
Purpose of the Study:
- To report the first Middle Eastern experience with the Alterra Adaptive Pre-Stent.
- To evaluate the safety, feasibility, and early outcomes of TPVR using this system in patients with complex RVOT anatomies.
Main Methods:
- A retrospective, single-center analysis was conducted at Prince Sultan Cardiac Center, Riyadh, Saudi Arabia.
- Ten patients with native or surgically patched RVOTs underwent TPVR using the Alterra Pre-Stent and Edwards SAPIEN 3 valve between April and July 2025.
- Patient selection, procedural data, and early clinical outcomes were reviewed.
Main Results:
- All 10 patients (mean age 30 ± 7.1 years) underwent successful implantation with 100% procedural success.
- Device positioning was accurate, with no significant residual gradient or pulmonary regurgitation.
- No major complications occurred, and all patients remained clinically stable with improved functional status at a median follow-up of 31 days.
Conclusions:
- This study represents the first reported experience of the Alterra Adaptive Pre-Stent in the Middle East.
- Early results indicate the device is safe, technically feasible, and effective in selected patients with complex RVOT anatomies.
- The Alterra Pre-Stent may broaden the applicability of TPVR in the region.