Correlation between Cardiac Electrophysiological Indicators and Lipid Parameters in Coronary Heart Disease with
1Department of Cardiology, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University.
Abstract:
This study assessed the relationship between cardiac electrophysiological indicators and blood lipid parameters in patients with coronary artery disease complicated by arrhythmia and evaluated their combined influence on the development of heart failure. A cohort of 240 patients admitted to the Cardiac Center of The First Affiliated Hospital of Xiamen University between April 2023 and April 2025 was screened; 80 met the inclusion criteria and were included in the analysis. Participants were categorized according to the occurrence of heart failure. Clinical characteristics, including lipid profiles (triglycerides, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and total cholesterol), were analyzed alongside echocardiographic parameters, including left ventricular ejection fraction (LVEF) and carotid intima-media thickness (CIMT). Statistical analyses included correlation testing, multivariable logistic regression, and receiver operating characteristic (ROC) curve analysis. Impaired cardiac function, increased CIMT, and abnormal lipid concentrations were significantly associated with heart failure risk. QTc interval showed positive correlations with LDL-C (r = 0.342, P < 0.01) and triglycerides (r = 0.366, P < 0.01), whereas HDL-C showed inverse correlations with electrocardiographic parameters. In multivariable logistic regression analysis, prolonged QTc interval (OR = 1.08, 95% CI: 1.02-1.15), widened QRS duration (OR = 1.05, 95% CI: 1.01-1.11), elevated LDL-C (OR = 1.74, 95% CI: 1.12-2.63), increased triglycerides (OR = 1.62, 95% CI: 1.05-2.48), reduced HDL-C (OR = 0.68, 95% CI: 0.50-0.91), and decreased LVEF (OR = 0.89, 95% CI: 0.83-0.94) were independent predictors of heart failure. ROC analysis confirmed the predictive value of multiple risk factors, with AUCs ranging from 0.68 to 0.75. HDL-C had the highest predictive accuracy individually (AUC = 0.75), while QTc interval and LVEF also demonstrated strong discrimination (AUC = 0.73).
More Related Videos
10:41Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology
Published on: September 13, 2022
04:41Digital PCR for Quantifying Circulating MicroRNAs in Acute Myocardial Infarction and Cardiovascular Disease
Published on: July 3, 2018
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Mechanism of Cardiac Arrhythmias
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease I: Introduction
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
