Evaluating Breast Implants Characteristics and Replacements in BIA-ALCL Onset: A Multicenter Case-Control study
Fabio Santanelli di Pompeo1, Demosthenes Panagiotakos2, Mark Warren Clemens3
1Chair of Plastic Surgery, Faculty of Medicine and Psychology, Sapienza University of Rome, Department of Neuroscience, Mental Health and Sense Organs (NESMOS), Sant'Andrea University Hospital, Rome, Italy.
Breast Implant-Associated Anaplastic Large Cell Lymphoma (BIA-ALCL) risk is linked to implant roughness >10µm. Surgeons and patients should consider implant surface texture in breast implant decisions.
Area of Science:
- Oncology
- Plastic Surgery
- Biomaterials Science
Background:
- Breast Implant-Associated Anaplastic Large Cell Lymphoma (BIA-ALCL) is a rare cancer associated with textured breast implants.
- The relationship between specific implant characteristics and BIA-ALCL development requires further investigation.
Purpose of the Study:
- To investigate the association between breast implant characteristics (surface texture, volume, manufacturer) and replacement history with the risk of developing BIA-ALCL.
- To provide evidence-based guidance for surgeons and patients regarding implant selection to minimize BIA-ALCL risk.
Main Methods:
- A multicenter, retrospective case-control study involving 327 women without malignancy and 94 BIA-ALCL cases.
- Analysis of surgery indication, implant manufacturer, volume, surface texture, indwelling time, and replacement history.
- Conditional logistic regression was used to assess associations with BIA-ALCL.
Main Results:
- All BIA-ALCL cases were associated with implants having roughness >10µm.
- Increased implant volume correlated with a higher likelihood of BIA-ALCL (OR per 100cc = 1.81).
- Breast reconstruction was linked to lower BIA-ALCL odds (OR = 0.53) compared to cosmetic augmentation; implant replacement also reduced risk (OR = 0.18).
Conclusions:
- No association was found between BIA-ALCL and specific implant manufacturers or roughness <10µm.
- Breast implant surface roughness should be a key consideration for surgeons and patients during treatment decisions.
- These findings support informed choices for primary or secondary breast implant procedures to mitigate BIA-ALCL risk.