Biological Indicators and Process Challenge Devices for Nitrogen Dioxide Sterilization
Abstract:
Few data have been published regarding the use of biological indicators (BIs) for nitrogen dioxide (NO2) sterilization. This article presents findings from a comprehensive series of studies conducted to assess BI performance across common circumstances: transport, shelf life, integration within self-contained BIs (SCBIs), poststerilization handling, and incubation. The results showed that BIs retained their performance characteristics after transport and for up to 12 months of storage postmanufacture. During sterilization, SCBIs functioned reliably as external process challenge devices (PCDs) for NO2 processes. Following sterilization, external PCDs could be held for up to 48 hours prior to activation and incubation without compromising results. BI growth outcomes can be finalized in as little as 42 hours, enabling timely product release. These findings confirmed the reliability of BIs for NO2 sterilization and support their use in validation and routine monitoring of NO2 sterilization processes.
More Related Videos
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Bioreactor Controls-I
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Bioreactor Controls-II