Accuracy of the Pulsox-Me500, a pulse oximeter with built-in accelerometer, as an obstructive sleep apnea screening
Satoshi Hamada1, Hironobu Sunadome2, Kimihiko Murase1
1Department of Advanced Medicine for Respiratory Failure, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
Abstract:
The Pulsox-Me500, a pulse oximeter equipped with a built-in three-axis accelerometer, was recently developed by Konica Minolta, Inc. However, its accuracy of screening obstructive sleep apnea (OSA) has not been investigated, and this was the aim of our study. Participants simultaneously used the Pulsox-Me500 and a SleepScope (a portable one-channel electroencephalography device) in the residential setting and wore this device during polysomnography in the inpatient setting. An interclass correlation coefficient (ICC) (2,1) value of 0.4-<0.75 and ≥ 0.75 was considered fair to good and excellent level of reliability, respectively. Sleep time measured by the Pulsox-Me500 was closely associated with total sleep time measured by the SleepScope (ICC (2,1), 0.77). And, 3% oxygen desaturation index measured by the Pulsox-Me500 was more closely associated with that measured by polysomnography when corrected for sleep time measured by the Pulsox-Me500 (ICC (2,1), from 0.74 to 0.84). The Pulsox-Me500 can efficiently screen for OSA.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...