Related Experiment Video
Updated: May 8, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Accuracy of VO2 max Estimates From Apple Watch Series 10
Rory Lambe1,2, Moritz Schumann3, Lauren Donnelly1
1School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin, Ireland.
Objective:
To assess the validity of maximal oxygen uptake (VO2 max) estimates from Apple Watch Series 10 through comparison with indirect calorimetry, the criterion method.
Participants And Methods:
Participants completed a maximal exercise treadmill test using indirect calorimetry in accordance with the modified Åstrand protocol. They subsequently generated a VO2 max estimate with Apple Watch Series 10. The agreement between Apple Watch and indirect calorimetry was assessed using Bland-Altman analysis, mean absolute error, and mean absolute percentage error. Data were collected between October 2024 and January 2025.
Results:
Forty healthy adults (20 [50%] women) completed exercise testing. Apple Watch underestimated VO2 max overall, with wide limits of agreement indicating measurement variability (mean difference, -6.25 mL/kg per minute [95% CI, -8.28 to -4.23]; limits of agreement, -18.23 to 5.73). The mean absolute error was 6.79 mL/kg per minute (95% CI, 4.91-8.67), and the mean absolute percentage error was 13.2% (95% CI, 9.6-16.8). Based on reference standards from the Fitness Registry and the Importance of Exercise National Database, Apple Watch correctly classified the cardiorespiratory fitness percentile of 5 (14%) participants and classified a further 12 (34%) within 1 adjacent percentile band of their actual band.
Conclusion:
Apple Watch VO2 max estimates showed poor individual-level agreement with criterion measures, although our findings suggested utility for population-level assessment in research trials. Longitudinal validation of measurement reliability is needed to evaluate use as an alternative to conventional submaximal prediction methods.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Special considerations while measuring pulse
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Measurement of Blood Pressure
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: