Related Experiment Video
Updated: May 9, 2026

Laryngeal Mask Airway (LMA) Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway (SGA)
Published on: July 14, 2023
Clinical evaluation of the i-gel Plus supraglottic airway in Japanese patients: A prospective observational study
Toshiyuki Nakanishi1, Ayaka Tani1, Kei Matsumoto1
1Department of Anesthesiology and Intensive Care Medicine, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
Background:
The i-gel® Plus, a new supraglottic airway, has a high oropharyngeal leak pressure of 32 ± 7 cmH2O in the European population. Because the i-gel® series was developed based on the laryngeal anatomy in Western populations, its performance in other regions, such as East Asia, is unknown. Therefore, we aimed to perform an initial clinical evaluation of i-gel® Plus in Japanese patients.
Methods:
This prospective observational study, conducted from March to June 2024 at a university hospital in Japan, recruited a total of 64 adult patients, 16 each of nonelderly (18-69 years) male, nonelderly female, elderly (≥ 70 years) male, and elderly female patients. Patients with a suspected high risk of aspiration or a predicted difficult airway were excluded. We recorded the oropharyngeal leak pressure (primary outcome), first-attempt success rate, and fiberoptic views of the i-gel® Plus. Continuous variables were evaluated for normality using the Shapiro-Wilk test and Q-Q plot. The groups were stratified by age and sex for exploratory analysis.
Results:
Of the 67 enrolled patients, three were excluded: one 70-year-old male because of failed ventilation and two because of missing data. Finally, 64 patients were analyzed, with 16 patients in each age-sex group. The oropharyngeal leak pressure was 23.7 ± 6.9 (mean ± standard deviation) cmH2O, which was normally distributed based on the Shapiro-Wilk normality test (P = 0.593) and Q-Q plot. The first-attempt success rate was 92% (including one failed ventilation case), and visible vocal cords were observed in 80% of cases. In exploratory comparisons by sex, male patients had lower oropharyngeal leak pressure and fewer visible vocal cords than female patients.
Conclusions:
The i-gel® Plus showed a high first-attempt success rate of 92%; however, its oropharyngeal leak pressure was lower than expected at 23.7 ± 6.9 cmH2O in this Japanese cohort.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...