Related Experiment Video
Updated: May 9, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
A machine learning approach predicts improvement of physical exercise capacity based on pulse wave analysis in
Hendrik Schäfer1, Vassilis Tsakanikas2, René Garbsch1
1Department of Rehabilitation Sciences, Faculty of Health, University of Witten/Herdecke, Witten 58455, Germany; DRV Clinic Königsfeld, Center for Medical Rehabilitation, Ennepetal 58256, Germany.
Background:
Patients with stable coronary artery disease (CAD) have a residual risk of adverse events and all-cause mortality. Enhancing exercise capacity by exercise training (ET) during cardiac rehabilitation (CR) is a Class 1A guideline recommendation. However, there is a high number of ET non-responders (NR) in CR. We aimed to develop a machine learning (ML) prediction model for the early identification of NR using baseline cardiopulmonary exercise testing (CPET) and pulse wave analysis (PWA) data.
Methods:
Participants included 393 CAD patients after myocardial infarction and/or percutaneous coronary intervention and/or coronary artery bypass graft who underwent 3-4 weeks of CR; CPET was conducted at the beginning and end of CR. Responders (R) were defined as participants who demonstrated an increase in exercise capacity (peak oxygen uptake (V̇O₂peak)) greater than 1 typical error away from 0, all other patients were defined as NR. Only baseline data including diagnosis, medication, PWA, and CPET data were used for modeling, and ML models included 10 different supervised algorithms. The dataset was split into training and test sets, and 10-fold cross-validation was used. Recursive Feature Elimination was used for feature selection to reduce dimensionality and improve generalizability. Independent external validation was performed in a dataset of CAD patients (n = 120) enrolled at 2 different centers (Germany and Spain). Predictions were explained using the model-agnostic SHapley Additive exPlanation methodology.
Results:
After data cleaning, 353 patients (20.4% women) with age of 55.8 ± 7.1 years (mean ± SD) were included for analysis, and 225 patients (63.7%) were classified as NR (22% women; age = 56.2 ± 7.1 years). ET participation rates were similar (R: 93.6% ± 7.5%; NR: 92.6% ± 9.3%; p = 0.764). For the prediction model, the Random Forest classifier provided the best mean balanced accuracy of 77.0%. The most influential features were breathing reserve/frequency, oxygen uptake combined with pulse wave velocity, cardiac output, and augmentation time. Of note, primary diagnosis and disease severity had only limited influence on the model. External validation of the Random Forest model showed 82.8% accuracy, with high specificity and moderate sensitivity in long-term outcome prediction.
Conclusion:
The developed ML-based model enables an early identification of ET NR, allowing individual patient-centered ET adaptations to improve CR.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...