Clinical characterization of membrane oxygenator exhaust capnometry during venovenous extracorporeal membrane
John W Stokes1, Whitney D Gannon2, Elizabeth Simonds3
1Department of Thoracic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.
Abstract:
Capnometry is a cost-efficient method of monitoring carbon dioxide (CO2) in healthcare settings, especially during mechanical ventilation and cardiopulmonary bypass. However, the utility of capnometers for studying CO2 elimination in a longer-duration, clinical extracorporeal membrane oxygenation (ECMO) has been poorly characterized. This report presents data from 10 venovenous ECMO patients at Vanderbilt University Medical Center between April and June 2021. Exhaust CO2 was intermittently measured from a membrane oxygenator's gas outlet, and arterial blood samples were simultaneously drawn from the patient. Clinical variables including ECMO and ventilator management, patient demographics, and outcomes were recorded. Exhaust CO2 and other study variables were recorded at 233 discrete time points from the 10 patients. The median duration of ECMO support was 9 days. Sweep gas flow rate demonstrated a strong, negative correlation with exhaust CO2 concentration, from both univariate and multivariate regression analyses (adjusted β = - 5.556 for sweep < 4 L/min, p < 0.001). Blood flow, oxygenator duration of use, and arterial CO2 demonstrated weaker relationships with exhaust CO2 (adjusted β = 2.341, - 0.258, 0.175, respectively), which agrees with the clinical understanding about CO2 management during ECMO. This descriptive study provides foundation for future research to precisely define the clinical role of ECMO exhaust capnometry in the management of the sweep gas flow and the overall therapy.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...