Investigation of Intraoperative Bacterial Contamination in Surgical Instruments Used for Total Hip Arthroplasty

Akihito Oya1,2, Noboru Matsumura1,2, Atsuhiro Fujie1

  • 1Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan.

Arthroplasty Today
|May 8, 2026
PubMed
Abstract

Insights

Reusing surgical instruments for bilateral hip replacements is generally safe, but obese patients may have a higher risk of contamination. Strict infection control is essential.

Area of Science:

  • Orthopedic Surgery
  • Infectious Disease Control
  • Surgical Instrumentation

Background:

  • Reusing surgical instruments in bilateral total hip arthroplasty (THA) can lower costs but may increase infection risks.
  • Femoral broaches, used in canal preparation, are a potential source of periprosthetic joint infections.

Purpose of the Study:

  • To evaluate the safety of reusing surgical instruments during simultaneous bilateral total hip arthroplasty.
  • To assess the bacterial contamination of femoral broaches in THA procedures.

Main Methods:

  • Prospective analysis of 78 primary THA cases (January 2021-October 2022).
  • Bacterial sampling of femoral broaches after the first hip in bilateral procedures.
  • Categorization by operative duration (<90 min vs. ≥90 min) and comparison between culture-positive and negative groups.

Main Results:

  • Bacterial contamination (skin commensals) was found in 3.8% of cases.
  • No periprosthetic joint infections were reported.
  • Higher body weight and BMI were associated with positive cultures, not operative time.

Conclusions:

  • While instrument reuse appears safe with stringent controls, bacterial contamination can occur.
  • Obese patients present a higher risk for contamination, requiring increased vigilance.
  • Strict infection control measures are crucial for safe surgical instrument reuse in THA.