Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Cryogenic Gas-phase IR Spectroscopy on a Commercial Ion Mobility-Mass Spectrometry Platform
Gergo Peter Szekeres1,2, Jacob S Jordan1,2, Jerome Riedel1,2
1Department of Chemistry, Biochemistry, and Pharmacy, Freie Universität Berlin, Altensteinstraße 23A, Berlin 14195, Germany.
Abstract:
The combination of gas-phase infrared (IR) spectroscopy with ion mobility spectrometry and mass spectrometry provides detailed, multidimensional structural information that facilitates the identification of unknown analytes. The instrumentation for performing these measurements is typically home-built and requires substantial expertise to operate. Here, we demonstrate messenger-tagging IR spectroscopy on a modified Synapt G2-S ion mobility-mass spectrometer (IM-MS). Messenger-tagging is performed in a commercially available cryogenic ion trap inserted between the exit of the transfer cell and the TOF pusher assembly, and tagged ions are excited by IR light before MS measurement. We report the adjustments to the timing cycle and voltage gradient in the Synapt G2-S necessary for efficient trapping and messenger-tagging in the cryogenic trap. The capabilities of this instrument are demonstrated by measuring IM-MS-IR data for leucine enkephalin, a benchmark standard in mass spectrometry. The ability to selectively transmit ions of specific mobility enables the separation and subsequent IR spectroscopy of the isomeric trisaccharides cellotriose and melezitose. These data demonstrate the first implementation of messenger-tagging IR spectroscopy in a widely used, commercially available IM-MS system. The user-friendly implementation of these techniques overcomes a significant barrier to the widespread incorporation of orthogonal IR spectroscopy measurements in existing IM-MS workflows and will aid in distinguishing unknown molecules in untargeted -omics measurements.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Chemical Ionization (CI) Mass Spectrometry
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
IR Spectrometers
Applications of IR Spectroscopy: Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences