Related Experiment Video
Updated: May 10, 2026

06:54
Performing Repeated Intraoperative Impedance Telemetry Measurements during Cochlear Implantation
Published on: August 4, 2023
MI-SI-R: A Mini-Invasive, Drill-Free, Anchor-Free Subperiosteal Reverse Technique for Active Bone Conduction
Pierre-François Dolhen1, Jean-Marc Gerard2, Morgan Potier3
1Clinique Causse-MSP Narbonne, Narbonne, France.
Summary
The mini-invasive subperiosteal reverse (MI-SI-R) technique offers a safe and feasible drill-free method for active bone conduction implantation, showing promising audiological results. This tissue-sparing approach preserves periosteum and avoids bone drilling for improved outcomes.
Area of Science:
- Otolaryngology
- Biomedical Engineering
- Neurosurgery
Background:
- Bone conduction devices are crucial for hearing restoration in specific patient groups.
- Traditional implantation methods can involve invasive drilling and anchoring.
- The development of minimally invasive techniques is essential for improving patient outcomes and device usability.
Purpose of the Study:
- To assess the feasibility, safety, and preliminary audiological results of the mini-invasive subperiosteal reverse (MI-SI-R) technique.
- To evaluate a novel screw-free and drill-free approach for active piezoelectric bone conduction device implantation.
- To explore the potential benefits of the reverse implant orientation for external processor placement.
Main Methods:
- A retrospective, single-center feasibility study was conducted on 14 patients (15 procedures).
- The MI-SI-R technique involved a small incision and an endoscopically created subperiosteal pocket without bone drilling or anchoring.
- Audiological outcomes (PTA, SRT, overclosure) and complications were assessed over a mean follow-up of 19.6 months.
Main Results:
- Significant improvements in Pure-Tone Average (PTA) by 55.1 dB and Speech Recognition Threshold (SRT) by 20.2 dB were observed at 3 months in mixed hearing loss patients.
- A mean overclosure of 19.2 dB HL was noted, indicating effective bone conduction transmission.
- One minor complication (magnet extrusion) occurred, successfully managed with device replacement; no implant migration was observed.
Conclusions:
- The MI-SI-R technique is a safe, feasible, and mini-invasive option for active bone conduction implantation.
- This drill-free, anchor-free approach preserves periosteum and offers encouraging short-term audiological outcomes.
- Further multicenter studies are needed to confirm long-term efficacy and explore pediatric applications.
