Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using
Henri Leroy1, Adrien Bertolo1, Guillaume Goudot2
1Physics for Medicine Paris, INSERM U1273, ESPCI Paris, PSL University, CNRS, Paris, France.
Abstract:
Accurate volumetric velocity estimation is crucial in ultrasound imaging for both diagnostic and therapeutic applications. Traditional ultrasound systems, though effective for two-dimensional imaging, face major limitations in 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes offer a promising alternative by reducing hardware complexity, thereby reducing the gap between research prototypes and clinical systems. However, this typically comes at the expense of stronger sidelobes compared with fully populated matrix arrays, leading to reduced image contrast. Several approaches have been proposed to improve the contrast of power Doppler imaging, yet the accuracy and performance of velocity Doppler estimation have received comparatively little attention. In this study, we present a method that exploits the phase information from RCA row and column signals to derive a novel velocity estimator based on cross-correlation of orthogonal apertures. This extends the XDoppler scheme, initially developed for power Doppler imaging, to velocity estimation. The XDoppler estimator is shown to provide accurate measurements of axial velocities and to outperform the traditional phase-shift autocorrelator, while offering a theoretical Nyquist velocity twice as high. In vitro experiments further demonstrate enhanced sensitivity to slow flows and reduced bias in flow rate estimation. In vivo data from a carotid artery confirm the reduced sensitivity to aliasing and reveal the ability to track dynamic blood flow velocity changes associated with arterial pulsatility. These findings suggest that the XDoppler velocity estimator could improve volumetric velocity imaging in clinical contexts.
Related Concept Videos
Doppler Effect - II
Average and Instantaneous Velocity Vectors
Doppler Effect - I
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...