Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
Dual-shot polarization digital holographic microscopy with phase bias equalization for full-field Jones matrix
Mohammad M T R Hussein1,2, M Fatih Toy1,2,3
1Department of Biomedical Engineering, Istanbul Medipol University, 34810 Beykoz, Istanbul, Turkey.
Abstract:
Polarization digital holographic microscopy (PDHM) enables noninvasive, quantitative mapping of birefringence via full-field Jones matrix analysis. Conventional implementations rely on multiple sequential acquisitions and are vulnerable to phase drift, whereas single-shot variants are optically complex and alignment sensitive. We introduce a simple dual-shot PDHM that reconstructs the full-field Jones matrix from two holograms acquired with orthogonal incident polarizations. A motorized half-wave plate sets the input states, and a polarization-sensitive CMOS camera records off-axis holograms that embed four analyzer channels per exposure. To suppress inter-shot phase drift, we propose a phase bias equalization that leverages isotropic reference regions to align complex phases across Jones elements. Experiments on biaxially oriented polypropylene (BOPP) films yield retardance and fast axis maps in agreement. Imaging of mouse brain sections and human cornea further demonstrates robust visualization of anisotropic microstructures. The method balances speed, hardware simplicity, and quantitative performance, offering an accessible route to polarization-sensitive biomedical imaging and full-field Jones matrix microscopy.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Two-Dimensional Microscopy in Microbiology
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)