Related Experiment Video
Updated: May 12, 2026

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
MW-FlexNIRS: wearable, low-cost, LED-based, multi-wavelength NIRS oximeter for cytochrome c oxidase recovery in
Nikola Otic1, Mitchell B Robinson1, Kuan-Cheng Wu1
1Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts, USA.
Abstract:
We present MW-FlexNIRS, a wearable, low-cost, LED-based, multi-wavelength near-infrared spectroscopy (NIRS) system designed for continuous monitoring of cerebral oxygenation and metabolic dynamics in neonates. The device extends the original FlexNIRS platform by integrating custom eight-wavelength LED sources, a new analog front-end, and Bluetooth low energy 5 communication onto a single flexible printed circuit board encapsulated in medical-grade silicone. To support quantitative analysis with broadband LED sources, we introduce a wavelength-weighted fitting (WWF) algorithm that explicitly accounts for LED emission spectra, photodiode responsivity, and tissue optical properties. System performance was characterized through spectral calibration, stability testing, and noise equivalent power measurements, yielding an average NEP of 123 ± 25 fW/√Hz. Validation experiments using solid silicone phantoms demonstrated accurate recovery of effective attenuation coefficients with a mean error of 2.1% using a calibrated multi-distance approach. Liquid phantom studies incorporating blood, Intralipid, and yeast were used to evaluate recovery of hemoglobin and to investigate cytochrome c oxidase (CCO) related spectral sensitivity, parameter coupling, and model limitations. Finally, a pilot measurement in a term infant with transient respiratory distress demonstrates the preliminary feasibility of stable, continuous cerebral oxygenation monitoring in the neonatal intensive care unit. Together, these results support MW-FlexNIRS as a promising platform for multi-wavelength wearable NIRS in neonates and highlight both the potential and current challenges of oxCCO quantification.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...

