Fractional approach to solve water infiltration problem in an unsaturated porous medium by combined Natural transform

Mahesh Puri Goswami1, Sonu Jatrana1, Mahaveer Prasad Yadav2

  • 1Department of Mathematics and Statistics, Mohanlal Sukhadia University, Udaipur 313001, India.

Related Concept Videos

Indefinite Integrals01:25

Indefinite Integrals

The water inflow rate into a storage tank is not constant but increases over time. Initially, the pump delivers water at a rate of 5 L/min. However, the inflow rate increases by 2 L/min for each additional minute due to rising pressure or system adjustments. This scenario can be described mathematically by a linear function:It is necessary to integrate the inflow rate function to measure the total volume of water added to the tank over time. The total water volume V(t) is obtained by performing...
Fundamental Theorem of Calculus I: Problem Solving01:22

Fundamental Theorem of Calculus I: Problem Solving

In many engineering and environmental applications, accumulated quantities are determined from rates that vary over time. A common example arises in water management, where a supply system pumps water into a storage tank at a rate that changes with time. Accurately determining how much water has entered the tank over a given period is essential for maintaining proper pressure, scheduling operations, and ensuring system safety.The flow rate of water into the tank is described by a time-dependent...
Control Volume and System Representations01:16

Control Volume and System Representations

Two key frameworks are employed to analyze mass, energy, and momentum transfer: the control volume approach and the system approach. These frameworks offer different perspectives, depending on whether the focus is on a specific region in space (control volume approach) or a defined mass of fluid (system approach).
The control volume approach considers a stationary region in space through which fluid flows. This region is bounded by a control surface.  For instance, in the case of water flowing...
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
Gradually Varying Flow01:29

Gradually Varying Flow

Gradually varying flow (GVF) in open channels describes situations where water depth changes slowly along the channel due to factors like non-uniform bed slope, channel shape variations, or obstructions. This flow type occurs when the depth adjusts gradually to balance gravitational forces, shear forces, and energy requirements, resulting in a low rate of depth change.Characteristics of Gradually Varying FlowGVF is commonly observed in natural streams, rivers, and canals, where flow depth...
Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...