Antibiotic-Associated Overanticoagulation Unmasking Prosthetic Valve Endocarditis Diagnosed by
José A Sánchez Aguirre1, Gladis Faustino Maravilla2, Ana K Garro Almendaro2
1Internal Medicine, Centro Médico Nacional 20 de Noviembre, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Mexico City, MEX.
Abstract:
Vitamin K antagonists (VKAs) remain the standard anticoagulation therapy in patients undergoing mechanical valve replacement; despite their efficiency in this clinical context, they are associated with a very narrow therapeutic window, a factor that links them to a major risk of bleeding. Their broad involvement in the coagulation cascade and their interactions with multiple commonly used drugs can lead to supratherapeutic anticoagulation. Furthermore, prosthetic valve infective endocarditis is a serious complication that poses a diagnostic challenge, especially when echocardiographic findings are inconclusive. We present the case of a 50-year-old man with a mechanical aortic valve prosthesis secondary to severe aortic stenosis, on anticoagulation therapy with acenocoumarol, who presented with severe over-anticoagulation, with multiple hemorrhagic complications, including hemothorax, chronic subdural hematoma, and extensive intramuscular hematomas involving the iliopsoas muscle and deep compartments of the thigh. The onset of these complications was temporally associated with the administration of an antibiotic regimen containing amoxicillin, secondary to an upper respiratory tract infection. During his hospital stay, persistent fever and the isolation of Enterococcus faecalis from central and peripheral blood cultures raised suspicion of probable infective endocarditis; however, both transthoracic and transesophageal echocardiograms were inconclusive for vegetations. Therefore, positron emission tomography (PET) with fluorodeoxyglucose (FDG) combined with computed tomography (CT) was performed, revealing focal hypermetabolic uptake around the prosthetic aortic valve annulus, consistent with prosthetic valve endocarditis; targeted antimicrobial therapy was initiated, and the patient was subsequently referred for surgical valve replacement, which was performed after the completion of antibiotic treatment with satisfactory clinical progress. This case highlights the vast clinical consequences of anticoagulation instability associated with VKAs, and especially the exponential increase in risk due to drug interactions, as in this case, linked to antibiotic therapy. Furthermore, it emphasizes the value of FDG-PET/CT in the diagnosis of prosthetic valve endocarditis, particularly when echocardiographic findings are inconclusive.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)