Related Experiment Video
Updated: May 14, 2026
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Preclinical characterization of a novel FAP-targeted PET tracer, [68Ga]Ga-CB6NT-FAPI
Hye Yeon Seo1, Hwa Sil Kim2, Ran Ji Yoo3
1Department of Biomedical Sciences, Seoul National University Graduate School, Seoul, Republic of Korea; Cancer Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea; Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Abstract:
Fibroblast activation protein (FAP) is an established target for molecular imaging of the tumor stroma. In this study, we report the development and preclinical evaluation of a novel FAP-targeted positron emission tomography (PET) tracer, [68Ga]Ga-CB6NT-FAPI. [68Ga]Ga-CB6NT-FAPI was efficiently radiolabeled under mild conditions (room temperature, 10 min), yielding high radiochemical purity (>99.9%) and demonstrating excellent in vitro stability. In vitro studies showed significantly higher uptake in FAP-positive cells than in FAP-negative cells, which was reduced by excess unlabeled ligand, confirming FAP-specific binding. In vivo PET/MR imaging in a U87MG xenograft model demonstrated clear tumor uptake with favorable contrast. Blocking studies resulted in a marked reduction in tumor signal, and ex vivo biodistribution confirmed specific tumor accumulation with an approximately 99.9% reduction under blocking conditions. The tracer exhibited partial hepatobiliary involvement in addition to renal clearance. These findings indicate that CB6NT-FAPI represents a pharmacokinetically differentiated FAPI tracer that expands the diversity of FAP-targeted PET imaging by providing an alternative balance between renal and hepatobiliary clearance.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)