A Cyclic Self-Calibration Method Based on a High-Precision Piston and Standard-Meter Water Flow Prover
Xuemei Geng1, Yanwei Yang1, Xuxin Dong1
1National Urban Energy Measurement Centre (Zhejiang Province), Zhejiang Institute of Quality Sciences, Hangzhou 310018, China.
None:
The standard meter water flow prover is widely used due to its mature technology and high work efficiency. However, the process of sending the standard meter for calibration is not only time-consuming and laborious but also introduces deviations due to differences in installation and operating conditions. Therefore, by leveraging the high precision, convenient adjustment, and simple traceability of the piston prover, as well as the good repeatability of the standard meter, this paper proposed a cyclic self-calibration method, which iteratively transmits the calibrated piston value to different flow points of the standard meter through the standard meter itself and the transition flow meter, so as to realize the in situ transmission of the value from the high-precision piston to the wide range of standard meter. The water flow standard device and the cyclic self-calibration method, combining the standard meter and the transfer meter in series and parallel, were introduced; the uncertainty transfer chain was analyzed based on the error transfer theory; and experimental validation was conducted. The results show that the proposed self-calibration method is feasible, that the (0.005~4) m3/h high-precision flow rate of the piston can be extended to the (4~1250) m3/h of standard meters through multiple self-calibration value transfers, and that the expanded uncertainty of the water flow standard device is better than 0.20% (k = 2).
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...