Related Experiment Video
Updated: May 14, 2026

An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Real-Time Gait Analysis of the Pelvis and Lower Limbs Using a Seven-Node IMU Network
Xiao Wang1, Lin Wang1, Liangyang Luo1
1College of Electronics and Information, Qingdao University, Qingdao 266071, China.
Abstract:
To address limited segment coverage and integration drift in wearable inertial gait analysis, this work proposes a real-time multi-segment gait analysis method using seven MEMS-IMUs deployed on the pelvis and lower limbs. The method employs parameter adaptive nonlinear complementary filtering and foot-based event detection to calculate spatiotemporal parameters and joint angles. Validation against optical motion capture (OMC) showed sagittal joint angle RMSEs below 2.37°, pelvic angle RMSEs below 0.96°, and correlation coefficients above 0.89 during normal walking in healthy adults. Supported by real-time 3D skeletal visualization, the proposed system provides a low-cost and portable solution for quantitative gait assessment under controlled walking conditions, with potential for future rehabilitation monitoring after further clinical validation.