Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Effect of Thermal Processing on Surface Roughness of Injection-Molded Denture Base Polymers
Bozhana Chuchulska1, Mariya Dimitrova1, Boyan Dochev2,3
1Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria.
None:
Surface roughness and mechanical performance are critical determinants of the clinical behavior, hygiene, and longevity of denture base materials. This study investigated the influence of two extrusion temperatures-280 °C and 300 °C-on both the surface roughness and compressive strength of ThermoSens thermoplastic polymer specimens over a 7-day immersion period. Surface roughness was evaluated at baseline, 24 h, and 7 days using a contact profilometer, while compressive strength was measured after 7 days following ISO 604 guidelines. Samples processed at 300 °C exhibited a significantly greater reduction in surface roughness over time (28.3%) compared with those processed at 280 °C (18.3%). However, although specimens processed at 300 °C showed a greater percentage reduction, their absolute roughness values remained higher than those processed at 280 °C. Compression testing demonstrated higher strength and modulus values in the 300 °C group (91.6 ± 1.8 MPa; 1887.9 ± 42.3 MPa) compared to the 280 °C group (82.3 ± 2.1 MPa; 1755.4 ± 38.7 MPa). These findings indicate a trade-off between improved mechanical performance at higher processing temperatures and lower surface roughness at lower temperatures, highlighting the need for the careful optimization of processing conditions.