Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Rapid Strength Prediction of HTV Silicone Rubber Composite Insulators Based on Aging Characteristics
Zhijin Zhang1, Yao Shen1, Shude Jing1
1Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, School of Electrical Engineering, Chongqing University, Huxi Campus, Chongqing 400044, China.
None:
To investigate the inevitable aging of composite insulators under the coupled effects of electrical, thermal, ice, and fog stresses, as well as to explore their aging mechanisms and residual strength prediction methods, this study collected operational insulator samples from four environmental regions: Tibet, Yunnan, Hunan Xuefeng Mountain, and Anhui/Chongqing. Mechanical properties, including tensile strength, elongation at break, and shear resistance, were tested. The results indicate that the degradation of mechanical performance in composite insulation components can be attributed to the synergistic interaction of operational environments and material characteristics, with the aging behavior of high-temperature vulcanized (HTV) silicone rubber exhibiting significant non-linearity. Based on existing research, molecular dynamics simulations were employed to construct microstructural models at different aging stages, and it was verified that main chain scission, reduced system density, and changes in the elemental chemical environment during aging are closely related to the degradation of material mechanical properties. Based on hyper-elastic constitutive theory and fracture mechanics, a quantitative method for assessing the comprehensive aging degree was proposed, with "service years" and "operational altitude" as the core dimensions. A negative exponential model was established to describe the strength degradation of silicone rubber materials. This model enables the non-destructive estimation of the residual mechanical strength of in-service insulators in complex regions without power interruption, providing a decision-making framework for grid operation and maintenance.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
11:17Synthesis of Programmable Main-chain Liquid-crystalline Elastomers Using a Two-stage Thiol-acrylate Reaction
Published on: January 19, 2016
Related Concept Videos
Impact Strength of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Fatigue Strength of Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...