Related Experiment Video
Updated: May 14, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
The effect of boosted injection of saline on contrast effect in angiography
Takashi Iwasaki1,2, Hajime Sakamoto3, Masaki Kuwabara4
1Department of Radiology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan. t-iwasaki@juntendo.ac.jp.
Abstract:
To evaluate the effect of saline boost injections on angiographic contrast. Angiographic examinations were performed using a SIEMENS ArtisQ Celling (VD11E) system with syngo Workplace (VD20B) and a PRESS DUO elite autoinjector (Nemoto Kyorindo, Tokyo). Standard injection parameters, assuming non-selective angiography from the abdominal aortic bifurcation to the common femoral artery, were 5.0 mL/s for 2.0 s. Five boost conditions were assessed: injection speed of 5.0, 7.0, and 10.0 mL/s with total volumes of 5.0, 10.0, and 15.0 mL (1.0-3.0× standard), and 7.0 and 10.0 mL volumes corresponding to the amount delivered within 1.0 s. Time-enhancement curves (TECs) were generated from identical regions of interest placed in the proximal, middle, and distal portions of a vascular phantom to measure maximum signal intensity and enhancement duration. Additional quantitative analysis was performed using iFlow color-coded maps. Changes in the saline-flush boost volume resulted in minor differences compared with the baseline TECs. At a boost speed of 7.0 mL/s, maximum signal intensity increased by 7.2%, 8.1%, and 7.0% in the proximal, middle, and distal segments. At 10.0 mL/s, increases were 11.5%, 11.3%, and 11.1%, respectively. On iFlow analysis, the reference time-to-peak significantly shortened at 10.0 mL/s-3.49, 4.01, and 4.17 s-compared with 3.68, 4.22, and 4.26 s at baseline (p < 0.01). Boosting double-speed saline injection improved the efficiency of contrast agent delivery to distal regions. Further improvements in injection efficiency may reduce the required amount of contrast agent and the number of frames.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

