Related Experiment Video
Updated: May 15, 2026

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Novel imaging protocol enables myelography of the cervical vertebral column using computed tomography with flexion
Background:
Radiographic myelography is the traditional diagnostic method for detecting cervical spinal cord compression in horses but it is limited by superimposition and restriction to sagittal plane imaging. Computed tomography (CT) and CT myelography overcome many of these limitations yet previous CT protocols have not allowed dynamic imaging in flexion and extension comparable to radiographs.
Objectives:
To describe and evaluate a novel CT myelography protocol that enables imaging of the equine cervical vertebral column (C2/3 to C7/T1) in flexion, neutral, and extension, and to compare intervertebral angle measurements with those obtained from radiographic myelography.
Study Design:
Prospective clinical study.
Methods:
Eight horses with clinical signs related to the cervical vertebral column underwent CT myelography and radiographic myelography under general anaesthesia. A mobile gantry CT system combined with a custom support platform enabled controlled repositioning of the cervical vertebral column. Intervertebral angles (C2/3 to C6/T1) were measured in flexion, neutral, and extension by three blinded image reviewers. Agreement between modalities was assessed using ANOVA, Bland-Altman plot, and concordance correlation coefficients.
Results:
The entire dynamic CT myelography protocol was completed within 45 min. Across all positions and cervical segments, no statistically significant differences were found between CT and radiographic myelography angle measurements (p > 0.01). All horses recovered uneventfully from anaesthesia, and no contrast-related adverse effects were observed.
Main Limitations:
Small sample size and the absence of repeated intra-observer measurements. Intervertebral angles served as a proxy for motion but did not directly assess the degree of spinal cord compression.
Conclusions:
Dynamic CT myelography is feasible, safe, and provides positional sensitivity comparable to radiographic myelography, while overcoming the limitations of superimposition and enabling multiplanar evaluation. This novel protocol offers a reliable diagnostic alternative for assessing cervical spinal pathology in horses and allows complete coverage of the cervical vertebral column from C2 to T1.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies for Cardiovascular System V: CT