Related Experiment Video
Updated: May 15, 2026

Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
Experimental assessment of ultrasound and EDTA effects on multi-heavy metal retention in forward osmosis: a
Mahdie Yazdani1, Reza Ghiassi1, Zahra Akbari1
1Water and Environmental Measurement and Monitoring Laboratory, School of Civil Engineering, College of Engineering, University of Tehran, Tehran, Iran.
Abstract:
The acidic nature of mine water results in elevated concentrations of heavy metals, implying significant pressures on aquatic ecosystems. Mine water treatment consists of objectives: reducing environmental harm by removing contaminants and providing alternative water sources and enabling metal recovery. This study employed forward osmosis to evaluate the treatment of simulated mine water, investigating the effects of draw solution concentration (0.5 and 1 M EDTA), pH levels (4, 7, and 9), ultrasonic parameters (frequencies of 28 kHz and 40 kHz with continuous and pulsed operation modes), and membrane orientation. The research specifically investigated the effect of time as a key factor in evaluating retention changes of heavy metals (Pb, Zn, Fe). The overall trend in metal retention efficiency exhibited a gradual decline over time, primarily influenced by various operational factors. Continuous ultrasonication enhanced performance when the support layer faced the feed solution, whereas pulsed mode was more effective with the active layer, yielding rejection efficiencies in the order Fe < Pb < Zn. Differential Scanning Calorimetry (DSC) revealed that ultrasonic vibrations during FO led to the highest glass transition temperature (Tg = 62.75°C), confirming a greater average water flow (AWF) in US-FO-28 compared to the baseline. Ultrasonication increased the crystallinity index (CI) of the membrane by 42% relative to the pristine membrane. Atomic Force Microscopy (AFM) further supported these improvements, showing a decrease in root mean square roughness (Rq) at 28 kHz.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
EDTA: Auxiliary Complexing Reagents
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Complexometric EDTA Titration Curves