Background:
Diagnostic errors (DEs) are common in patients who die or go to the intensive care unit (ICU), due to gaps in diagnostic processes, but it is unclear if this holds true for sepsis patients.
Objectives:
To determine whether patients with sepsis, as defined by International Classification of Disease-10 (ICD-10) code, have a different DE risk and/or underlying diagnostic process faults compared with other patients who die or are admitted to an ICU.
Methods:
We conducted a retrospective cohort study of two thousand four hundred and twenty-eight adult patients discharged from 29 academic medical centers in 2019 were included in the vizient clinical database and the hospital medicine re-engineering network, meeting centers for medicare & medicaid services criteria for a "medical" admission. Patients included either died in-hospital or were admitted to the ICU during the studied admission. Safer Dx and diagnostic error evaluation and research (DEER) taxonomy defined DE and diagnostic process faults, respectively. Adjusted risk ratios (aRRs) for DE were estimated using modified Poisson regression clustered by site. Interaction terms tested differences between patients with and without sepsis.
Results:
Of 1218 sepsis patients (50.2%), DE rates were similar to nonsepsis patients (22.3% vs. 23.9%, p = .734). Adjusted analysis showed no association between sepsis and DE (aRR: 1.06, 95% confidence interval [CI]: 0.91-1.23). Sepsis was less strongly associated with DE if gaps in history-taking (interaction-term p = .02) or consultation problems (interaction-term p = .005) were present. No other DEER interactions were significant.
Conclusion:
Sepsis was not associated with a higher adjusted risk for DEs or individual diagnostic process faults, suggesting diagnostic issues in sepsis are tied to broader clinical care problems rather than sepsis-specific factors.
Related Concept Videos
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters assessment...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Errors occurring during blood pressure monitoring
Several factors...
Automated Microbial Diagnostics
Urine Studies II: Urine Culture and Sensitivity Test