Related Experiment Video
Updated: May 16, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Reliability of point-of-care glucose in neonates: revisiting hypoglycemia protocols in the NICU
Ibrahim Hamama1, Vikram Katodia1, Natalie M Landry2,3
1Department of Pediatrics and Child Health, Section of Neonatology, Max Rady College of Medicine, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Canada.
Objectives:
Hypoglycemia is a common metabolic problem in newborns, often asymptomatic but can lead to cognitive impairment and neuromotor delays. This study assesses the practicality and accuracy of whole blood capillary bedside glucose measurements using a point-of-care (POC) glucometer compared to serum glucose levels obtained via laboratory methods. The objective of this article was to evaluate the reliability of POC glucose levels in the NICU and compare them with central laboratory glucose measurements.
Methods:
A retrospective cross-sectional comparative study was conducted on 108 newborns admitted to the NICU at the Health Science Center, Winnipeg, Manitoba, Canada, between September 2022 and August 2024. Hypoglycemic POC glucose results from the Nova Stat Strip glucose meter were compared to confirmatory central laboratory serum glucose results produced on the Roche cobas c501 analyzer.
Results:
A significant correlation was observed between serum glucose levels and glucometer readings, with a correlation coefficient of 0.825. Regression analyses showed a slope of 1.223 (Deming) and 1.200 (Passing-Bablok), with intercepts of -0.75 and -0.70, respectively.
Conclusions:
Accurate blood glucose measurement is critical for early detection and management of neonatal hypoglycemia. Given the reliability of current glucometers and their close correlation to serum samples, this study questions the need for confirmatory serum samples in the presence of bedside hypoglycemic results.
Related Concept Videos
Hypoglycemia and Glucagon
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Hypoglycemia
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility, suggesting a...
Hyperglycemia

