Related Experiment Video
Updated: May 17, 2026

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Determinants of Titanium Hardware Exposure Following Cranioplasty: A Case-Control Study
Katerina Green1, Rockey Dahiya1, Natalie Weiss1
1Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic.
Objectives:
Despite advantages of titanium mesh, hardware exposure affects up to 25% of cases reported in the literature. We aim to identify risk factors associated with titanium mesh exposure following cranioplasty and characterize early wound changes that may signal impending hardware exposure.
Methods:
A review of 34 patients who underwent titanium mesh cranioplasty between 2015 and 2025 was performed. Seventeen patients with hardware exposure were matched 1:1 with 17 controls. Data on demographics, comorbidities, operative details, and postoperative complications were collected. Statistical analysis included Fisher exact test and t tests, with significance set at P<0.05.
Results:
Significant risk factors for titanium hardware exposure included a history of metal allergy and reconstruction with advancement flaps. Significant protective factors included patients undergoing postoperative radiation therapy and reconstruction with rotational flaps.
Conclusions:
Titanium mesh exposure risk increases with metal allergy history, postoperative radiotherapy, and use of advancement flaps for reconstruction. Recognition of early wound changes is crucial for timely intervention. These findings support individualized surgical planning and highlight the need for close postoperative monitoring to reduce complications and improve reconstructive outcomes.