Related Experiment Video
Updated: May 17, 2026

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Adverse Cardiac Effects of Ultrasonic Vaping Devices Despite Lack of Heating Coil
Natasha Goyal1, Maansa Kavuri1, Ping Wang2
1Division of Cardiology, University of California, San Francisco, San Francisco CA United States.
Introduction:
Ultrasonic vaping devices like SURGE are marketed as safer alternatives to conventional coil-based electronic cigarettes like JUUL due to their lower operating temperatures. However, their impact on cardiovascular health has not been fully characterized.
Methods:
Sprague-Dawley rats were exposed daily for 9 weeks to aerosol generated from SURGE, JUUL, or clean air. Heart rate variability (HRV) was continuously monitored via implanted telemetry. Cardiac fibrosis was quantified using histological analysis. Temperature profiles of SURGE, JUUL, and Nautilus (a coil-based tank device) were recorded. Aerosol samples were analyzed for carbonyl compounds using high-performance liquid chromatography.
Results:
Both SURGE and JUUL exposures significantly reduced HRV (high frequency and total power) compared to air. JUUL exposure significantly increased cardiac fibrosis; SURGE showed a similar mean fibrosis level but greater variability, resulting in a nonsignificant difference. SURGE devices operated at lower peak temperatures (~131°C) than JUUL (~239°C) and Nautilus (~160-170°C). Despite it having the lowest temperature, SURGE emitted higher levels of carbonyl compounds than JUUL, although still substantially lower than Nautilus.
Conclusions:
Although SURGE operates without coils and at lower temperatures than coiled vaping devices, it generates higher levels of carbonyls than some coiled devices and impairs cardiac autonomic regulation, and it can cause cardiac fibrosis comparable to JUUL although with high variability; that is, SURGE does not reliably avoid the increase in fibrosis caused by conventional e-cigarettes. These findings suggest that non-thermal mechanisms predominate in mediating cardiovascular toxicity associated with ultrasonic vaping, challenging the assumption that coil-free designs are inherently safer.
Implications:
Despite its lower operating temperature and coil-free design, the SURGE ultrasonic vaping device impaired cardiac autonomic function and promoted fibrosis at a mean level comparable to that of JUUL. These findings challenge claims of reduced harm from coil-less vaping technologies and suggest that non-thermal mechanisms may drive toxicity. Regulatory evaluations should consider device emissions and physiological outcomes-not just hardware features. Physicians and policymakers should be aware that coil-less systems may still pose cardiovascular risks, and marketing these devices as inherently safer may mislead users and undermine tobacco harm reduction efforts.
More Related Videos
10:44Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Related Concept Videos
Stimulants
Cocaine can be administered via snorting, injection, or smoking. It primarily functions by blocking the reuptake of dopamine, resulting in a euphoric high characterized by an intense sensation of happiness and...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Mechanism of Cardiac Arrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...