Related Experiment Video
Updated: May 19, 2026

From Molecules to Materials: Engineering New Ionic Liquid Crystals Through Halogen Bonding
Published on: March 24, 2018
Design of fluorinated cross-linked poly(ionic liquid) stationary phases for green liquid chromatography and multiple
Xiang Wang1, Zhiwei Zou2, Jie Liu2
1Key Laboratory of Micro-Nano Powder and Advanced Energy Materials of Anhui Higher Education Institutes, Chizhou University, Chizhou, Anhui 247000, PR China.
Abstract:
Green liquid chromatography has garnered increasing attention due to heightened environmental awareness among the public. In this work, a cross-linked poly(ionic liquid)-modified stationary phase was developed and was further functionalized with fluorine using 2,3,4,5,6-pentafluorostyrene. Chromatographic evaluations demonstrated the comprehensive separation capabilities of the mixed-mode HILIC/RPLC/IEX configuration, highlighting the potential to replace multiple single-mode columns with a mixed-mode column. High repeatable retention was achieved in green per aqueous liquid chromatography. The fluorine modification enhanced the stationary phase's capacity to separate organic halides and their isomers. Finally, this stationary phase was used to separate and detect multiple analytes in everyday products, achieving satisfactory relative standard deviations (RSDs) and recoveries that typically require diverse columns and instruments under conventional methods. Overall, the results underscore the advantages of preparing green chromatography stationary phases using cross-linked poly(ionic liquid), as well as the superiority of mixed-mode chromatography for diverse routine analyses.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process