Detecting, Visualizing and Quantitating the Generation of Reactive Oxygen Species in an Amoeba Model System
Published on: November 5, 2013
Impact of BHT Additive on the Optical and Reactive Behavior of Fluorescent Peroxynitrite Probes
An V Pham1, Emile J Morin1, Shivshankar R Mane1,2
1Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
None:
Peroxynitrite (ONOO-) is a reactive oxygen and nitrogen species that is central to oxidative stress and pathophysiological signaling. Fluorescent small-molecule chemicals have been widely employed for detecting peroxynitrite, also known as peroxynitrite-responsive probes (PRPs). However, the influence of common solvent stabilizers on sensor performance remains insufficiently examined. Here, we report the impact of a ubiquitous stabilizer, trace amounts of butylated hydroxytoluene (BHT), a frequently used antioxidant in organic solvents (i.e., tetrahydrofuran, diethyl ether, and isopropyl ether), which significantly alters the baseline optical properties and the apparent reactivity of model fluorescent probes with peroxynitrite. Utilizing UV-visible spectroscopy, fluorescence spectroscopy, and nuclear magnetic resonance (NMR), our results demonstrate that BHT has an impact at concentrations as low as 0.25 μM, which is ∼103-104-fold lower than the typical 900-1800 μM found in standard 4 L solvent bottles. The stabilizer (1) induces absorption baseline elevation near 310 nm, (2) partially distorts the probe's emission band, and results in a (3) loss of phenolic proton signal consistent with oxidation products in CD3CN after exposure to ONOO-. These effects lead to an artificially suppressed apparent sensor response, corresponding to a 98% decrease in the expected signal. Our findings demonstrate that the presence of BHT in commercial solvents can compromise analytical peroxynitrite sensor assays, especially those reliant on short-wavelength (≤350 nm) excitations. This further emphasizes the need to consider stabilizer impurities when fabricating PRPs for both fundamental studies and translational applications.
More Related Videos
09:33Imaging Approaches to Assessments of Toxicological Oxidative Stress Using Genetically-encoded Fluorogenic Sensors
Published on: February 7, 2018
08:01Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo
Published on: September 26, 2016
Related Concept Videos
Variables Affecting Phosphorescence and Fluorescence
Regioselectivity of Electrophilic Additions-Peroxide Effect