Diagnostic performance of contrast-enhanced mammography and MRI for breast non-mass microcalcifications: a novel Malignant Calcification Score in contrast-enhanced mammography
Related Experiment Video For Breast neoplasms
Updated: May 19, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Jun Chen1, Bei Hua2, Yang Zhao3
1Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
Background:
Non-mass microcalcifications present a significant diagnostic challenge in breast imaging, highlighting the urgent need for more objective and accurate tools to enhance the specificity of pre-biopsy evaluations for suspicious non-mass microcalcifications. This study aims to develop a novel Malignant Calcification Score (MCS) using contrast-enhanced mammography (CEM) to characterize malignant microcalcifications and to compare its diagnostic performance with the established Breast Imaging Reporting and Data System (BI-RADS).
Methods:
A cohort of 99 patients presenting with non-mass-associated microcalcifications was stratified into benign and malignant groups based on definitive pathological diagnoses. Logistic multiple regression and receiver operating characteristic (ROC) analysis were performed to identify independent predictors and to establish MCS. Its diagnostic performance was evaluated and compared with BI-RADS for mammography (MG) and magnetic resonance imaging (MRI).
Results:
In low-energy imaging, microcalcification morphology and distribution patterns showed statistically significant differences between benign and malignant lesions (all P<0.05). In the recombined images, enhancement descriptors-including the percentage signal difference (in the craniocaudal oblique view) [%RS(CC)], modified time-intensity curve (mTIC), enhancement morphological distribution, and internal enhancement pattern-served as independent predictors of malignancy (all P<0.05), with %RS(CC) specifically predictive of invasive carcinoma (P=0.007). The MCS demonstrated high diagnostic performance [area under the curve (AUC): 0.908-0.930], significantly outperforming both BI-RADS (MG) (AUC: 0.678-0.679) and BI-RADS (MRI) (AUC: 0.724) (DeLong's test: all P<0.05).
Conclusions:
The MCS introduces a novel diagnostic framework by integrating key descriptors from low-energy and recombined CEM images, demonstrating superior performance compared to BI-RADS standards. Its clinical application helps reduce diagnostic uncertainty and decreases the rate of unnecessary biopsies.