Related Experiment Videos
Evaluating StyleGAN2-ADA and f-AnoGAN for GAN based unsupervised anomaly detection in gastrointestinal endoscopy
Amit Kumar Bairwa1, Aryan Sinha1, Satpal Singh Kushwaha2
1Department of Artificial Intelligence and Machine Learning, School of Computer Science and Engineering, Manipal University Jaipur, Jaipur, 303007, India.
None:
Manual interpretation of gastrointestinal (GI) endoscopy images is a subjective and time-intensive process, often leading to variability between clinicians and the risk of missed abnormalities. To address these challenges, we investigate the use of StyleGAN2-ADA as a generative model for unsupervised anomaly detection in gastrointestinal endoscopy images. StyleGAN2-ADA combines adaptive discriminator augmentation with style-based generative modelling, enabling the model to capture both global anatomical structures and fine-grained mucosal textures. In this work, the performance of StyleGAN2-ADA is empirically compared with the widely used f-AnoGAN framework to assess its suitability for anomaly detection in gastrointestinal endoscopy images. The model was trained and evaluated on the HyperKvasir dataset, a large and diverse collection of endoscopic images representing both normal and pathological findings. Our method achieved a ROC-AUC of 0.945 and an F1 score of 0.847, outperforming the established f-AnoGAN baseline in anomaly discrimination. These results highlight the ability of StyleGAN2-ADA to model complex multimodal distributions of healthy tissue and to emphasize abnormal regions as reconstruction defects. Clinically, this framework has the potential to support early detection of GI diseases and to integrate into real-time endoscopy workflows, reducing cognitive load for physicians, assisting less experienced clinicians, and accelerating biopsy decision-making.
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...